TSP Lab The Ethernet monitoring card handler module Sga-PacketDistributor

The Ethernet monitoring card handler module
("Sga-PacketDistributor")

The Poller connection feature

The Sga-PacketDistributor optionally can connect to Monitor Poller (Sga-7N-S) module of the Sga-7N monitoring system and can send events and statistical data to the about its states.
The related statistical codes should be added to the file "Sga-7N-1.lst" located beside the Statistics Query (Sga-7N-1) module. For the raw data to copy please
click here.
The event codes should be added to the file "Sga7N_GyDB_Lister_Event.lst" located beside the Event Lister (Sga7N_GyDB_Lister_Event) module. For the raw data to copy please click here.

Sga-PacketDistributor related events

For the event codes and descriptions please see the table below:
Event code Event Description
19 NTP error No answer from NTP server
20 Network error No network connection
21 Too high clock adjustment To much difference in time between the NTP server and the monitor unit (no clock adjustment done)
2010 No traffic in the last period No traffic seen on the given card in the last period.
The time period can be configured by the TrafficSamplingInterval entry in the card section.
The linkID refers to a single card stated in the card section by the InputLinkID entry
2011 All monitors connected All of the monitors are connected (again) to the poller
2012 At least 1 monitor not OK At least one monitor disconnected from the poller
2013 1GB signal detected Traffic detected (again) on the 1GB interface
2014 1GB signal lost Signal lost on the 1GB interface
2015 10GB signal detected Traffic detected (again) on the 10GB interface
2016 10GB signal lost Signal lost on the 10GB interface
2017 Bad frames Undecodable frames detected on the stream
2018 Lost frames Messages lost either on the input, or the output interface
2020 Unknown event Unknown event
2021 Sga-ClockCard configuration error Wrong configuration detected, please check the correct settings
2022 Sga-ClockCard communication lost Communication lost towards the Sga-ClockCard, please check the cabling
2023 Sga-ClockCard no link detected No network connection towards the Sga-ClockCard, please check the cabling
2024 Sga-ClockCard ARP timeout No ARP answer received
2025 Sga-ClockCard NTP timeout No NTP answer received
2026 Sga-ClockCard synchronization OK NTP sync succeeded
2027 Sga-ClockCard synchronization failed NTP sync failed
2028 Sga-ClockCard GPS OK GPS sync succeeded
2029 Sga-ClockCard GPS failed GPS sync failed

Sga-PacketDistributor related counters

For the statictical counter codes and descriptions please see the table below:
Counter Data Description
9003 No of recieved bytes Number of the received bytes in the last period. The time period can be adjusted with the StatisticsReportPeriod entry
9004 No of bad frames Number of the bad frames in the last period. The time period can be adjusted with the StatisticsReportPeriod entry
9005 No of lost frames Number of the lostframes in the last period. The time period can be adjusted with the StatisticsReportPeriod entry